2100 Series

Multi-Sensor – for the Ultimate Protection

New from Aico is the Multi-Sensor fire alarm. Up to now there have only been three types of alarm available – optical, heat and ionisation. Each one is best suited to a different fire type (e.g. flaming, smouldering etc.).

The Multi-Sensor changes all that. It has two sensors in it – optical and heat – so it gives the best response to all different fire types.

Contractor---WWWW---2110-Box

 

Ask-for-sticker-SmallEi2110
  • Two sensors - optical & heat
  • Responds to both slow smouldering fires (Sofas, TVs) and fast flaming fires (Papers, Clothing)
  • Mains powered with rechargeable Lithium back-up
  • Unique automatic 'Dust Compensation' reduces false alarms
  • 3rd party accredited by BSI to BS EN 14604:2005
 Contractor---WWWW---Alarm-Symbols-Multi-Sensor
*Guidance only. See BS 5839-6:2004 for full info
Contractor---WWWW---Works-With-Sticker-2100
Relay Base
Remote
Control Switch
Switched
Input Module
Ask-for-sticker-SmallEi128R
Ask-for-sticker-SmallEi1529RC
Ask-for-sticker-SmallEi129
Contractor---WWWW---Ei128R Contractor---WWWW---Ei1529RC Contractor---WWWW---Ei128R
  • Fits under alarms
  • Volt-free relay contacts
  • Ei128RBU available with battery back-up
  • Test and Silence alarms
  • Identify triggered alarm
  • Wire anywhere in the system 
  • Connect to switched contacts (e.g. sprinkler flow switch)
  • Triggers alarms when contacts close
Alarm for
Hearing Impaired
Carbon Monoxide
(CO) Alarm
Call Point
Ask-for-sticker-SmallEi169/160 Ask-for-sticker-SmallEi261ENRC Ask-for-sticker-SmallMCP401RC
Contractor---WWWW---Ei169-160 Contractor---WWWW---Ei261ENRC Contractor---WWWW---MCP401RC
  • Flashing Strobe
  • Vibrating pad for pillows
  • Mains with battery back-up
  • Mains with rechargeable back-up
  • Can interconnect with smoke alarms (must use Ei1529RC Switch)
  • No replacing glass
  • Reset with key
  • Wire anywhere in the system
RadioLINK
Professional Base
   
Ask-for-sticker-SmallEi168RC
   
Contractor---WWWW---Ei168RC    
  • Fits under alarms
  • Wireless interconnection - saves running interconnect cabling
   

2100 Series – RadioLINK

Multi-Sensor – for the Ultimate Protection

New from Aico is the Multi-Sensor fire alarm. Up to now there have only been three types of alarm available – optical, heat and ionisation. Each one is best suited to a different fire type (e.g. flaming, smouldering etc.).

The Multi-Sensor changes all that. It has two sensors in it – optical and heat – so it gives the best response to all different fire types.

RadioLINK-Professional-Logo-Small

Contractor---WWWW---2100-RadioLINK

 

Ask-for-sticker-SmallEi2110 plus Ei168RC
  • Two sensors - optical & heat
  • Responds to both slow smouldering fires (Sofas, TVs) and fast flaming fires (Papers, Clothing)
  • Mains powered with rechargeable Lithium back-up
  • Unique automatic 'Dust Compensation' reduces false alarms
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Multi-Sensor
*Guidance only. See BS 5839-6:2004 for full info
Contractor---WWWW---Works-With-Sticker-2100-with-168RC
Relay Module
Remote
Control Switch
Switched
Input Module
Ask-for-sticker-SmallEi428
Ask-for-sticker-SmallEi411H
Ask-for-sticker-SmallEi408
Contractor---WWWW---Ei428 Contractor---WWWW---Ei411H Contractor---WWWW---Ei408
  • Mains with rechargeable back-up
  • Volt-free relay contacts
  • Ei428SK available pre-wired for Warden Call
  • Test and Silence alarms
  • Identify triggered alarm
  • Battery powered (10 year life)
  • Ei412 available with CO indicator light
  • Connect to switched contacts (e.g. sprinkler flow switch)
  • Triggers alarms when contacts close
Alarm for
Hearing Impaired
Carbon Monoxide
(CO) Alarm
Call Point
Ask-for-sticker-SmallEi170RF Ask-for-sticker-SmallEi262 Ask-for-sticker-SmallEi407
Contractor---WWWW---Ei170RF Contractor---WWWW---Ei261ENRC Contractor---WWWW---Ei407
  • Mains with battery back-up
  • Strobe and vibrating pad for pillows
  • Ei171RF strobe only also available
  • Mains with rechargeable back-up
  • Wireless interconnection with smoke alarms (must use Ei412 Switch)
  • No replacing glass
  • Reset with key
  • Completely wireless
  • Battery powered (10 year life)
Repeater Module
   
Ask-for-sticker-SmallEi420
   
Contractor---WWWW---Ei420    
  • Mains powered
  • Repeats RF signals
  • Extends range
 

160RC Series

A range of mains powered alarms with rechargeable Lithium back-up, more suited to Social and Rented properties.

Optical

Contractor---WWWW---166RC-Box

 

Ask-for-sticker-SmallEi166RC
  • More responsive to smouldering fires (Sofas, TVs)
  • Proven optical sensor with insect screen to reduce false alarms
  • Mains powered with rechargeable Lithium back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Optical

Heat

Contractor---WWWW---164RC-Box

 

Ask-for-sticker-SmallEi164RC
  • Responds to heat build-up from large flaming fires
  • Heat sensor triggers at 58°C
  • Mains powered with rechargeable Lithium back-up
  • 3rd party accredited by BSI to BS 5446-2:2003
Contractor---WWWW---Alarm-Symbols-Heat

Ionisation

Contractor---WWWW---161RC-Box

 

Ask-for-sticker-SmallEi161RC
  • More responsive to flaming fires (Papers, Clothing)
  • Proven long life ionisation sensor
  • Mains powered with rechargeable Lithium back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Ionisation
*Guidance only. See BS 5839-6:2004 for full info
Contractor---WWWW---Works-With-Sticker-160RC
Relay Base
Remote
Control Switch
Switched
Input Module
Ask-for-sticker-SmallEi128R
Ask-for-sticker-SmallEi1529RC
Ask-for-sticker-SmallEi129
Contractor---WWWW---Ei128R Contractor---WWWW---Ei1529RC Contractor---WWWW---Ei128R
  • Fits under alarms
  • Volt-free relay contacts
  • Ei128RBU available with battery back-up
  • Test and Silence alarms
  • Identify triggered alarm
  • Wire anywhere in the system
  • Connect to switched contacts (e.g. sprinkler flow switch)
  • Triggers alarms when contacts close
Alarm for
Hearing Impaired
Carbon Monoxide
(CO) Alarm
Call Point
Ask-for-sticker-SmallEi169/160 Ask-for-sticker-SmallEi261ENRC Ask-for-sticker-SmallMCP401RC
Contractor---WWWW---Ei169-160 Contractor---WWWW---Ei261ENRC Contractor---WWWW---MCP401RC
  • Flashing Strobe
  • Vibrating pad for pillows
  • Mains with battery back-up
  • Mains with rechargeable back-up
  • Can interconnect with smoke alarms (must use Ei1529RC Switch)
  • No replacing glass
  • Reset with key
  • Wire anywhere in the system
RadioLINK
Professional Base
   
Ask-for-sticker-SmallEi168RC
   
Contractor---WWWW---Ei168RC    
  • Fits under alarms
  • Wireless interconnection - saves running interconnect cabling
 

160RC Series – RadioLINK

A range of mains powered alarms with rechargeable Lithium back-up. Compatible with RadioLINK Bases which allow wireless interconnection. More suited to Social and Rented properties.

RadioLINK-Professional-Logo-Small

Optical

Contractor---WWWW---166RC-RadioLINK-Box

 

Ask-for-sticker-SmallEi166RC plus Ei168RC
  • RadioLINK Base provides wireless interconnection
  • More responsive to smouldering fires (Sofas, TVs)
  • Proven optical sensor with insect screen to reduce false alarms
  • Mains powered with rechargeable Lithium back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Optical

Heat
Contractor---WWWW---164RC-RadioLINK-Box

 

Ask-for-sticker-SmallEi164RC plus Ei168RC
  • RadioLINK Base provides wireless interconnection
  • Responds to heat build-up from large flaming fires
  • Heat sensor triggers at 58°C
  • Mains powered with rechargeable Lithium back-up
  • 3rd party accredited by BSI to BS 5446-2:2003
Contractor---WWWW---Alarm-Symbols-Heat

Ionisation
Contractor---WWWW---161RC-RadioLINK-Box

 

Ask-for-sticker-SmallEi161RC plus Ei168RC
  • RadioLINK Base provides wireless interconnection
  • More responsive to flaming fires (Papers, Clothing)
  • Proven long life ionisation sensor
  • Mains powered with rechargeable Lithium back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Ionisation
*Guidance only. See BS 5839-6:2004 for full info
Contractor---WWWW---Works-With-Sticker-160RC-with-168RC
Relay Module
Remote
Control Switch
Switched
Input Module
Ask-for-sticker-SmallEi428
Ask-for-sticker-SmallEi411H
Ask-for-sticker-SmallEi408
Contractor---WWWW---Ei428 Contractor---WWWW---Ei411H Contractor---WWWW---Ei408
  • Mains with rechargeable back-up
  • Volt-free relay contacts
  • Ei428SK available pre-wired for Warden Call
  • Test and Silence alarms
  • Identify triggered alarm
  • Battery powered (10 year life)
  • Ei412 available with CO indicator light
  • Connect to switched contacts (e.g. sprinkler flow switch)
  • Triggers alarms when contacts close
Alarm for
Hearing Impaired
Carbon Monoxide
(CO) Alarm
Call Point
Ask-for-sticker-SmallEi170RF Ask-for-sticker-SmallEi262 Ask-for-sticker-SmallEi407
Contractor---WWWW---Ei170RF Contractor---WWWW---Ei261ENRC Contractor---WWWW---Ei407
  • Mains with battery back-up
  • Strobe and vibrating pad for pillows
  • Ei171RF strobe only also available
  • Mains with rechargeable back-up
  • Wireless interconnection with smoke alarms (must use Ei412 Switch)
  • No replacing glass
  • Reset with key
  • Completely wireless
  • Battery powered (10 year life)
Repeater Module
   
Ask-for-sticker-SmallEi420
   
Contractor---WWWW---Ei420    
  • Mains powered
  • Repeats RF signals
  • Extends range
 

140 Series

A range of mains powered alarms with Alkaline battery back-up, for New Build and Private properties.

Optical

Contractor---WWWW---146-Box

 

Ask-for-sticker-SmallEi146
  • More responsive to smouldering fires (Sofas, TVs)
  • Proven optical sensor with insect screen to reduce false alarms
  • Mains powered with Alkaline battery back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Optical

Heat

Contractor---WWWW---144-Box

 

Ask-for-sticker-SmallEi144
  • Responds to heat build-up from large flaming fires
  • Heat sensor triggers at 58°C
  • Mains powered with Alkaline battery back-up
  • 3rd party accredited by BSI to BS 5446-2:2003
Contractor---WWWW---Alarm-Symbols-Heat

Ionisation

Contractor---WWWW---141-Box

 

Ask-for-sticker-SmallEi141
  • More responsive to flaming fires (Papers, Clothing)
  • Proven long life ionisation sensor
  • Mains powered with Alkaline battery back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Ionisation
*Guidance only. See BS 5839-6:2004 for full info
Contractor---WWWW---Works-With-Sticker-140
Relay Base
Alarm
Locator Switch
Switched
Input Module
Ask-for-sticker-SmallEi128R
Ask-for-sticker-SmallEi159
Ask-for-sticker-SmallEi129
Contractor---WWWW---Ei128R Contractor---WWWW---Ei159 Contractor---WWWW---Ei128R
  • Fits under alarms
  • Volt-free relay contacts
  • Ei128RBU available with battery back-up
  • Identifies triggered alarm
  • Wire anywhere in the system
  • Connect to switched contacts (e.g. sprinkler flow switch)
  • Triggers alarms when contacts close
Alarm for
Hearing Impaired
Carbon Monoxide
(CO) Alarm
Call Point
Ask-for-sticker-SmallEi169/160 Ask-for-sticker-SmallEi261ENRC Ask-for-sticker-SmallMCP401RC
Contractor---WWWW---Ei169-160 Contractor---WWWW---Ei261ENRC Contractor---WWWW---MCP401RC
  • Flashing Strobe
  • Vibrating pad for pillows
  • Mains with battery back-up
  • Mains with rechargeable back-up
  • Can interconnect with smoke alarms (must use Ei1529RC Switch)
  • No replacing glass
  • Reset with key
  • Wire anywhere in the system
RadioLINK
Professional Base
   
Ask-for-sticker-SmallEi168RC
   
Contractor---WWWW---Ei168RC    
  • Fits under alarms
  • Wireless interconnection - saves running interconnect cabling
 

140 Series – RadioLINK

A range of mains powered alarms with Alkaline battery back-up. Compatible with RadioLINK Bases which allow wireless interconnection. More suited to Private properties.

RadioLINK-Professional-Logo-Small

Optical

Contractor---WWWW---146-RadioLINK-Box

 

Ask-for-sticker-SmallEi146 plus Ei168RC
  • RadioLINK Base provides wireless interconnection
  • More responsive to smouldering fires (Sofas, TVs)
  • Proven optical sensor with insect screen to reduce false alarms
  • Mains powered with Alkaline battery back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Optical

Heat

Contractor---WWWW---144-RadioLINK-Box

 

Ask-for-sticker-SmallEi144 plus Ei168RC
  • RadioLINK Base provides wireless interconnection
  • Responds to heat build-up from large flaming fires
  • Heat sensor triggers at 58°C
  • Mains powered with Alkaline battery back-up
  • 3rd party accredited by BSI to BS 5446-2:2003
Contractor---WWWW---Alarm-Symbols-Heat

Ionisation

Contractor---WWWW---141-RadioLINK-Box

 

Ask-for-sticker-SmallEi141 plus Ei168RC
  • RadioLINK Base provides wireless interconnection
  • More responsive to flaming fires (Papers, Clothing)
  • Proven long life ionisation sensor
  • Mains powered with Alkaline battery back-up
  • 3rd party accredited by BSI to BS EN 14604:2005
Contractor---WWWW---Alarm-Symbols-Ionisation
*Guidance only. See BS 5839-6:2004 for full info
Contractor---WWWW---Works-With-Sticker-140-with-168RC
Relay Module
Call Point
 
Switched
Input Module
Ask-for-sticker-SmallEi428
Ask-for-sticker-SmallEi407
Ask-for-sticker-SmallEi408
Contractor---WWWW---Ei428 Contractor---WWWW---Ei407 Contractor---WWWW---Ei408
  • Mains with rechargeable back-up
  • Volt-free relay contacts
  • Ei428SK available pre-wired for Warden Call
  • No replacing glass
  • Reset with key
  • Completely wireless
  • Battery powered (10 year life)
  • Connect to switched contacts (e.g. sprinkler flow switch)
  • Triggers alarms when contacts close
Alarm for
Hearing Impaired
Strobe for
Hearing Impaired
Repeater Module
Ask-for-sticker-SmallEi170RF Ask-for-sticker-SmallEi171RF Ask-for-sticker-SmallEi420
Contractor---WWWW---Ei170RF Contractor---WWWW---Ei171RF Contractor---WWWW---Ei420
  • Mains with battery back-up
  • Flashing strobe Vibrating pad for pillows
  • Vibrating pad for pillows
  • Mains with battery back-up
  • Flashing strobe only
  • For daytime rooms
  • Mains powered
  • Repeats RF signals
  • Extends range