Siting - Smoke Alarms


Contractor---WDIF---Siting-1 Contractor---WDIF---Siting-2
  • Mount centrally on the ceiling
  • Keep at least 300mm (12") from walls
  • Keep at least 300mm (12") from light fittings

 


 

 

Contractor---WDIF---Siting-3 Contractor---WDIF---Siting-4
  • There must be an alarm within 3m (10ft) of all bedroom doors
  • On peaked ceilings, mount 900mm (36") horizontally from the peak

 


 

 

Contractor---WDIF---Siting-5 Contractor---WDIF---Siting-6
  • Keep at least twice the depth away from any small obstructions, such as beams
  • Any obstruction greater than 10% of the room height should be treated as a wall
  • Extra alarms may be needed

Contractor---WDIS---Dos--Donts-1

Siting - Control Switches & Call Points

 

Contractor---WDIF---Siting-7
  • Mount 1.2m (4ft) from floor level
  • Control Switches should be mounted somewhere that's easy to access
  • Call points should be mounted by final exits from the building


Siting - Carbon Monoxide (CO) Alarms

Contractor---WDIS---With-appliance-text


Contractor---WDIS---CO-Siting-1 Contractor---WDIF---CO-Siting-2
  • Ceiling mounted
  • Between 1m and 3m horizontally from the appliance
  • Keep at least 300mm (12") from walls

 


 

Contractor---WDIF---CO-Siting-3
  • Keep at least 300mm (12") from light fittings

 

Contractor---WDIS---No-appliance-text

 

Contractor---WDIF---CO-Siting-4
  • Wall mounted
  • Fit at breathing height

Contractor---WDIS---Dos--Donts-2

Siting - Alarms for Hearing Impaired

 

 

Contractor---WDIS---Hearing-Impaired-1 Contractor---WDIS---Hearing-Impaired-2
  • Wall mounted
  • Strobe must be visible
  • Put vibrating pad under pillow