Ei208DW Carbon Monoxide Alarm

  • Proven Electrochemical sensor
  • 10 year Lithium sealed battery
  • LCD displays CO level, status messages and icons
  • Pre alarm LED and LCD display gives early warning of CO
  • Easy to fit twist on base and multi-fixings
AudioLINK RadioLINK+
British Standards Code

Product Description

The Ei208DW Carbon Monoxide Alarm is a Carbon Monoxide (CO) alarm that is powered by a sealed-in Lithium battery.

The alarm has a high performance, proven electrochemical sensor to detect CO presence. The sensor is individually calibrated and tested in CO gas on assembly to ensure accuracy.

The LCD displays CO level, status messages and icons.

The alarm has a twist on mounting base which has multiple fixing points so it can easily be secured to a ceiling or wall.

The memory feature records the last CO level sensed and can be useful to check if CO has been present if the home owner or tenant has been absent from the property.

An easy to use ‘Test/Hush’ button allows the user to test the alarm. This checks all aspects of the alarm (sensor, electronics and sounder).

The alarm has an ‘End of Life’ indicator which will notify the user when the alarm needs replacing.

Operation of the Ei208DW Carbon Monoxide Alarm

  • When dangerous levels of CO are detected, the LCD will display the CO concentration, the alarm will sound and the red alarm light will flash as detailed below.

  • When lower levels of CO are detected, the alarm will display a ‘Ventilate’ message. When higher levels are detected, the alarm will display an ‘Evacuate’ message.
  • If the alarm is reaching the end of life or a sensor fault is detected the alarm will display a ‘Replace Unit’ message and the amber fault light will flash three times every minute with three bleeps.
  • The ‘Test/Hush’ button will either silence false alarms (if briefly pressed) or perform a unit self test (if pressed and held). Note that the alarm cannot be silenced when sensing a CO level  of 150ppm or above.

Technical Specification

  • The CO alarm carries the BSI Kitemark to indicate type testing to BS EN 50291-1:2010 AND BS EN 50291-2:2010. It is CE marked to indicate conformance to BS EN 60335-1:1994, BS EN 50270:1999 Safety and Electromagnetic Compatibility Directives.
  • New generation electrochemical cell type Carbon Monoxide sensor checks CO concentration every 4 seconds, Each unit is calibrated and tested in CO gas in order to ensure accuracy.
  • Battery powered, sealed in Lithium battery that will power the unit for it’s entire life. The LCD will display a ‘Low Battery’ indicator and the amber fault light will flash twice every minute with two beeps to indicate that that the unit needs replacing.
  • Start up sequence – The red, amber and green LED’s will flash once.  Rapid warm up time – Once this very short sequence has elapsed, the alarm is in full operation.
  • CO level indicators as follows. The LCD display will also show the actual CO level in parts per million (PPM).
  • Fault Indicator – The LCD will display a ‘Replace Unit’ message and the amber fault light will flash twice every 50 seconds if a fault is detected.
  • End of Life Indicator – The LCD will display a ‘Replace Unit’ message and the amber fault light will flash three times every minute with three simultaneous beeps if the unit has reached its end of life.
  • Manual Test/Hush button – Press and hold the ‘Test/Hush’ button to test circuitry, sensor and sounder. LED’s will flash as below
    • Normal Mode – Green LED flash with normal alarm sound along with a tick on the LCD display
    • Fault Condition – Amber LED flash and LCD will display ‘Replace Unit’. Alarm will not sound.
    • End of Life – Amber LED flash will beep and LCD will display ‘Replace Unit’.
  • Pressing and releasing the ‘Test/Hush’ button when the unit is sensing CO will silence the alarm for 4 minutes. It will only silence once until the gas clears. At CO levels of 150ppm and above the unit cannot be silenced due to the increased danger.
  • Memory feature which records the last CO level sensed. If the unit has been in alarm and then ceased, the red LED will continue to flash for a 24 hour period to indicate the level of CO sensed. Pressing the ‘Test’ button will also show the last CO level sensed via the LCD  display and by the rate of flash of the red LED.
  • Built-in sounder to give a minimum output of 85dB(A) at 3 metres. Modulated sound output – 3 rapid pulses followed by a 1½ second pause, repeated until reset. This easily differentiates it from a typical smoke alarm.
  • Automatic reset of alarm test function and after an alarm state when CO gas clears.
  • Supplied with integral mounting base and fixing screws. The mounting base has multiple fixing holes and the alarm is suitable for ceiling or wall mounting.
  • Operating temperature range: -10°C to +40°C. 15% to 95% relative humidity (non-condensing).
  • Dimensions: 120mm x 105mm x 45mm. Weight 180g.
  • 5 year guarantee.
  • Manufactured in Ireland.

Downloads

Ei208DW Data Sheet

Download

Ei208DW Instructions

Download

The Ei208DW Carbon Monoxide Alarm is a Carbon Monoxide (CO) alarm that is powered by a sealed-in Lithium battery.

The alarm has a high performance, proven electrochemical sensor to detect CO presence. The sensor is individually calibrated and tested in CO gas on assembly to ensure accuracy.

The LCD displays CO level, status messages and icons.

The alarm has a twist on mounting base which has multiple fixing points so it can easily be secured to a ceiling or wall.

The memory feature records the last CO level sensed and can be useful to check if CO has been present if the home owner or tenant has been absent from the property.

An easy to use ‘Test/Hush’ button allows the user to test the alarm. This checks all aspects of the alarm (sensor, electronics and sounder).

The alarm has an ‘End of Life’ indicator which will notify the user when the alarm needs replacing.

Operation of the Ei208DW Carbon Monoxide Alarm

  • When dangerous levels of CO are detected, the LCD will display the CO concentration, the alarm will sound and the red alarm light will flash as detailed below.

  • When lower levels of CO are detected, the alarm will display a ‘Ventilate’ message. When higher levels are detected, the alarm will display an ‘Evacuate’ message.
  • If the alarm is reaching the end of life or a sensor fault is detected the alarm will display a ‘Replace Unit’ message and the amber fault light will flash three times every minute with three bleeps.
  • The ‘Test/Hush’ button will either silence false alarms (if briefly pressed) or perform a unit self test (if pressed and held). Note that the alarm cannot be silenced when sensing a CO level  of 150ppm or above.
  • The CO alarm carries the BSI Kitemark to indicate type testing to BS EN 50291-1:2010 AND BS EN 50291-2:2010. It is CE marked to indicate conformance to BS EN 60335-1:1994, BS EN 50270:1999 Safety and Electromagnetic Compatibility Directives.
  • New generation electrochemical cell type Carbon Monoxide sensor checks CO concentration every 4 seconds, Each unit is calibrated and tested in CO gas in order to ensure accuracy.
  • Battery powered, sealed in Lithium battery that will power the unit for it’s entire life. The LCD will display a ‘Low Battery’ indicator and the amber fault light will flash twice every minute with two beeps to indicate that that the unit needs replacing.
  • Start up sequence – The red, amber and green LED’s will flash once.  Rapid warm up time – Once this very short sequence has elapsed, the alarm is in full operation.
  • CO level indicators as follows. The LCD display will also show the actual CO level in parts per million (PPM).
  • Fault Indicator – The LCD will display a ‘Replace Unit’ message and the amber fault light will flash twice every 50 seconds if a fault is detected.
  • End of Life Indicator – The LCD will display a ‘Replace Unit’ message and the amber fault light will flash three times every minute with three simultaneous beeps if the unit has reached its end of life.
  • Manual Test/Hush button – Press and hold the ‘Test/Hush’ button to test circuitry, sensor and sounder. LED’s will flash as below
    • Normal Mode – Green LED flash with normal alarm sound along with a tick on the LCD display
    • Fault Condition – Amber LED flash and LCD will display ‘Replace Unit’. Alarm will not sound.
    • End of Life – Amber LED flash will beep and LCD will display ‘Replace Unit’.
  • Pressing and releasing the ‘Test/Hush’ button when the unit is sensing CO will silence the alarm for 4 minutes. It will only silence once until the gas clears. At CO levels of 150ppm and above the unit cannot be silenced due to the increased danger.
  • Memory feature which records the last CO level sensed. If the unit has been in alarm and then ceased, the red LED will continue to flash for a 24 hour period to indicate the level of CO sensed. Pressing the ‘Test’ button will also show the last CO level sensed via the LCD  display and by the rate of flash of the red LED.
  • Built-in sounder to give a minimum output of 85dB(A) at 3 metres. Modulated sound output – 3 rapid pulses followed by a 1½ second pause, repeated until reset. This easily differentiates it from a typical smoke alarm.
  • Automatic reset of alarm test function and after an alarm state when CO gas clears.
  • Supplied with integral mounting base and fixing screws. The mounting base has multiple fixing holes and the alarm is suitable for ceiling or wall mounting.
  • Operating temperature range: -10°C to +40°C. 15% to 95% relative humidity (non-condensing).
  • Dimensions: 120mm x 105mm x 45mm. Weight 180g.
  • 5 year guarantee.
  • Manufactured in Ireland.

Ei208DW Data Sheet

Download

Ei208DW Instructions

Download