Ei100R Ionisation Smoke Alarm

  • Dual ionisation chamber sensor
  • Built-in ‘Test’ button
  • Advanced suppression and calibration technology
  • Interconnectable with other 100R Series alarms
  • Volt free relay contact supplied
  • Kitemarked to BS EN14604:2005
  • 5 year guarantee
Suitable for:
British Standards Code

Product Description

The Ei100R Ionisation Smoke Alarm runs on a 12V DC power. The alarm gives a fire warning when adequate smoke enters the alarm.

The alarm has a pair of buil-in Volt free relay contacts (i.e. can be used to switch into a burglar panel).

The alarm has other advanced features, such as built-in circuitry to aid suppression of voltage transients and RF interference to further reduce the chances of false alarms under such conditions.

Operation of the Ei100R Ionisation Smoke Alarm

  • The red indicator on the front of the alarm will flash every 4o seconds to indicate mains power, and that it has performed an automatic self test.
  • The red indicator will flash rapidly to show an alarm condition for the alarm that has triggered.
  • In ‘Test’ mode the alarm will perform a self test and sound the horn.
  • When interconnected to other 100R series alarms, an alarm on one unit will trigger all other interconnected alarms (only the triggered alarm will flash a red indicator)

Technical Specification

  • The smoke alarm carries the BSI Kitemark to indicate type testing to BS EN14604:2005. It will meet the requirements of Grade D (and exceed the requirements of Grades E and F) as defined in BS 5839: Part 6: 2013. It carries the CE mark to indicate conformance to Electrical Safety and Electromagnetic Compatibility Directives.
  • Dual ionisation chamber sensor, with corrosion resistant electrodes, and insect resistant cover.
  • Built-in sounder giving a minimum sound output of 85dB (A) at 3m. Frequency range 2200/2800Hz. The diameter of the piezo disc in the sounder measures 40mm, and has wire contacts soldered directly on to the piezo disc. The sounder includes a resonator or ‘trumpet’ 30mm in length, which reaches to the lid of the outer casing in order to amplify the sound.
  • ‘Test’ button simulates the effects of smoke and tests sensor, electronics and horn.
  • Automatic ‘Self-Test’: Smoke chamber is tested every 40 seconds and unit bleeps if a fault is detected.
  • Interconnect feature, if one alarm sounds, all interconnected alarms will sound, up to 12 units may be interconnected using a low voltage multi core signal cable. Maximum resistance 20 Ohms. Can be interconnected with Ei100R, Ei105R and Ei103R alarms only.
  • Automatic reset facility – When smoke clears from the sensor, the smoke alarm will reset automatically.
  • Relay Contacts – Volt free with Normally Open and Normally Closed options and rated to 24 volts/1 Amp resistive.
  • Power on LED flashes every 40 seconds to confirm integrity of power supply.
  • Power supply: 10.2 to 14 Volts DC -normally supplied by compatible control panel.
  • Standby current: 150 microamps (max). Alarm current: 60 mA  (max), 30mA (min).
  • Airspeed: No false alarms up to 22mph.
  • Ambient Temperature Range: 4°C to 40°C. Humidity Range: 0 to 90% relative humidity.
  • Dimensions: 140 x 125 x 46mm.
  • Weight inclusive of packaging: 210g.
  • Manufactured in Ireland.
  • 5 year guarantee.

Downloads

Ei100R Data Sheet

Download

Ei100R Instructions

Download

The Ei100R Ionisation Smoke Alarm runs on a 12V DC power. The alarm gives a fire warning when adequate smoke enters the alarm.

The alarm has a pair of buil-in Volt free relay contacts (i.e. can be used to switch into a burglar panel).

The alarm has other advanced features, such as built-in circuitry to aid suppression of voltage transients and RF interference to further reduce the chances of false alarms under such conditions.

Operation of the Ei100R Ionisation Smoke Alarm

  • The red indicator on the front of the alarm will flash every 4o seconds to indicate mains power, and that it has performed an automatic self test.
  • The red indicator will flash rapidly to show an alarm condition for the alarm that has triggered.
  • In ‘Test’ mode the alarm will perform a self test and sound the horn.
  • When interconnected to other 100R series alarms, an alarm on one unit will trigger all other interconnected alarms (only the triggered alarm will flash a red indicator)
  • The smoke alarm carries the BSI Kitemark to indicate type testing to BS EN14604:2005. It will meet the requirements of Grade D (and exceed the requirements of Grades E and F) as defined in BS 5839: Part 6: 2013. It carries the CE mark to indicate conformance to Electrical Safety and Electromagnetic Compatibility Directives.
  • Dual ionisation chamber sensor, with corrosion resistant electrodes, and insect resistant cover.
  • Built-in sounder giving a minimum sound output of 85dB (A) at 3m. Frequency range 2200/2800Hz. The diameter of the piezo disc in the sounder measures 40mm, and has wire contacts soldered directly on to the piezo disc. The sounder includes a resonator or ‘trumpet’ 30mm in length, which reaches to the lid of the outer casing in order to amplify the sound.
  • ‘Test’ button simulates the effects of smoke and tests sensor, electronics and horn.
  • Automatic ‘Self-Test’: Smoke chamber is tested every 40 seconds and unit bleeps if a fault is detected.
  • Interconnect feature, if one alarm sounds, all interconnected alarms will sound, up to 12 units may be interconnected using a low voltage multi core signal cable. Maximum resistance 20 Ohms. Can be interconnected with Ei100R, Ei105R and Ei103R alarms only.
  • Automatic reset facility – When smoke clears from the sensor, the smoke alarm will reset automatically.
  • Relay Contacts – Volt free with Normally Open and Normally Closed options and rated to 24 volts/1 Amp resistive.
  • Power on LED flashes every 40 seconds to confirm integrity of power supply.
  • Power supply: 10.2 to 14 Volts DC -normally supplied by compatible control panel.
  • Standby current: 150 microamps (max). Alarm current: 60 mA  (max), 30mA (min).
  • Airspeed: No false alarms up to 22mph.
  • Ambient Temperature Range: 4°C to 40°C. Humidity Range: 0 to 90% relative humidity.
  • Dimensions: 140 x 125 x 46mm.
  • Weight inclusive of packaging: 210g.
  • Manufactured in Ireland.
  • 5 year guarantee.

Ei100R Data Sheet

Download

Ei100R Instructions

Download

Can't find what you're looking for?

Email support@aico.co.uk for more information